10 channels of H-bridge PWM output, 6 channels of 5A, 2 channels of 15A, 2 channels of reserved.
CANbus communication.
Operating voltage:DC 24V.
Short-circuit protection, over-voltage protection.
10 channels of 0-5V voltage inputs, and 10 channels of current feedback.
Operating Voltage
10-32VDC 380-530VAC |
Controller Limit Voltage
100VDC |
Controller Limit Current
100A(1mS) |
Dimensions
188*108*76.5mm |
Flexible Acceleration and Deceleration Control
Meets the requirements of different road conditions |
Communication Method
CAN2.0 protocol, fast data transmission, strong scalability, security and redundancy |
I/O Port
11channels(8 channels of DIH, 2 channels of DOH, 1 channel of 380V motor output) |
Operating Temperature
-40℃~ 75℃ |
Protection Level
IP65 |
Random Vibration
GB/T 2423.56-2018(IEC60068-2-64:1993) |
Mechanical Shock
GB-T2423.5-2019 (EC60068-2-27-2008) |
Sine Vibration
GB-T2423.10-2019(IEC 60068-2-6:1995) |
ESD
EN61000-4-2 |
EFT
EN61000-4-4:2004 |
Environmental Temperature
GB/T2423.1-2008 GB /T2423.2-2008 |
CE
IMMUNITY EN61000-6-2:2005 EMISSION EN61000-6-4:2007/A1:2011 |
EMC
Electrical Transient Conduction Immunity along the Power Line GB/T 21437.2-2008(ISO 7637-22004) Electrical Transient Immunity without Power Line Coupling GB/T 21437.3-2012 (1S0 7637-32007 |
0
0
Hotline:0086-021-37829910
Phone:+86 18916808200
Email:sales@smartsh.com
After submitting your information, our sales representative will contact you as soon as possible and send you the product documents.
Scan the QR code with WeChat and follow us to get in touch