Excellent shock and vibration resistance, specially designed CDS system function, protection level up to IP69K, very suitable for the construction machinery industry in the harsh working environment.
Developed for safety circuits/safety functions with safety ratings up to SIL2 (IEC61508) or PLd (ISO13849) safety standard.
Measurement Range (bar)
40 |
Overload Pressure (bar)
80 |
Burst Pressure (bar)
200 |
Mechanical Connection
G1/4 A |
Material of parts connected to the fluid
Stainless steel |
Output Signal
4 .. 20 mA |
Accuracy according to DIN 16086, terminal based
≤ ± 0.25 % FStyp. ≤ ± 0.5 % FS max. |
Accuracy(B.F.S.L.)
≤ ± 0.15 % FStyp. ≤ ± 0.25 % FS max. |
Zero/Range Temperature Drift
≤ ± 0.01 % FS / ° C typ. ≤ ± 0.01 % FS / ° C typ. |
Nonlinear according to DIN 16086, based on terminal
≤ ± 0.3 % FS max. |
Hysteresis
≤ ± 0.1 % FS max. |
Repeatability
≤ ± 0.1 % FS |
Rise Time
≤ 10 ms |
Long-term Stability
≤ ± 0.3 % FStyp. / year |
Compensation Temperature Range
-20 .. +85℃ |
Operating Temperature Range
-40 .. +100℃ /-25 .. +85℃ |
Storage Temperature Range
-40 .. +100℃ |
Fluid Temperature Range
-40 .. +125℃ /-25 .. +125℃ |
CE Certification
EN61000-6-1/2/3/4 |
Anti-vibration (DIN EN 60068-2-6 at 10 .. 2000 Hz)
≤ 20g |
Anti-impact (DIN EN 60068-2-27)
100 g / 6 ms / half-sine 500 g / 1 ms / half-sine |
Protection Level(DIN EN 60529)
IP67 |
Supply Voltage
9-36V |
Residual Ripple of Supply Voltage
≤ 5 % |
Current Consumption
≤ 25 mA |
Lifespan
> 10 million cycles , 0 .. 100 % FS |
Weight
~75g |
Measurement Rang (bar)
60 |
Overload Pressure (bar)
120 |
Burst Pressure (bar)
300 |
Mechanical Connection
G1/4 A |
Material of parts connected to the fluid
Stainless steel |
Output Signal
4 .. 20 mA |
Accuracy according to DIN 16086, terminal based
≤ ± 0.25 % FStyp. ≤ ± 0.5 % FS max. |
Accuracy(B.F.S.L.)
≤ ± 0.15 % FStyp. ≤ ± 0.25 % FS max. |
Zero/Range Temperature Drift
≤ ± 0.01 % FS / ° C typ. ≤ ± 0.01 % FS / ° C typ. |
Nonlinear according to DIN 16086, based on terminal
≤ ± 0.3 % FS max. |
Hysteresis
≤ ± 0.1 % FS max. |
Repeatability
≤ ± 0.1 % FS |
Rise Time
≤ 10 ms |
Long-term Stability
≤ ± 0.3 % FStyp. / year |
Compensation Temperature Range
-20 .. +85℃ |
Operating Temperature Range
-40 .. +100℃ /-25 .. +85℃ |
Storage Temperature Range
-40 .. +100℃ |
Fluid Temperature Range
-40 .. +125℃ /-25 .. +125℃ |
CE Certification
EN61000-6-1/2/3/4 |
Anti-vibration (DIN EN 60068-2-6 at 10 .. 2000 Hz)
≤ 20g |
Anti-impact (DIN EN 60068-2-27)
100 g / 6 ms / half-sine 500 g / 1 ms / half-sine |
Protection Level(DIN EN 60529)
IP67 |
Supply Voltage
9-36V |
Residual Ripple of Supply Voltage
≤ 5 % |
Current Consumption
≤ 25 mA |
Lifespan
> 10 million cycles , 0 .. 100 % FS |
Weight
~75g |
Measurement Range (bar)
100 |
Overload Pressure (bar)
200 |
Burst Pressure (bar)
500 |
Mechanical Connection
G1/4 A |
Material of parts connected to the fluid
Stainless steel |
Output Signal
4 .. 20 mA |
Accuracy according to DIN 16086, terminal based
≤ ± 0.25 % FStyp. ≤ ± 0.5 % FS max. |
Accuracy(B.F.S.L.)
≤ ± 0.15 % FStyp. ≤ ± 0.25 % FS max. |
Zero/Range Temperature Drift
≤ ± 0.01 % FS / ° C typ. ≤ ± 0.01 % FS / ° C typ. |
Nonlinear according to DIN 16086, based on terminal
≤ ± 0.3 % FS max. |
Hysteresis
≤ ± 0.1 % FS max. |
Repeatability
≤ ± 0.1 % FS |
Rise Time
≤ 10 ms |
Long-term Stability
≤ ± 0.3 % FStyp. / year |
Compensation Temperature Range
-20 .. +85℃ |
Operating Temperature Range
-40 .. +100℃ /-25 .. +85℃ |
Storage Temperature Range
-40 .. +100℃ |
Fluid Temperature Range
-40 .. +125℃ /-25 .. +125℃ |
CE Certification
EN61000-6-1/2/3/4 |
Anti-vibration (DIN EN 60068-2-6 at 10 .. 2000 Hz)
≤ 20g |
Anti-impact (DIN EN 60068-2-27)
100 g / 6 ms / half-sine 500 g / 1 ms / half-sine |
Protection Level(DIN EN 60529)
IP67 |
Supply Voltage
9-36V |
Residual Ripple of Supply Voltage
≤ 5 % |
Current Consumption
≤ 25 mA |
Lifespan
> 10 million cycles , 0 .. 100 % FS |
Weight
~75g |
Measurement Range(bar)
160 |
Overload Pressure (bar)
320 |
Burst Pressure (bar)
800 |
Mechanical Connection
G1/4 A |
Material of parts connected to the fluid
Stainless steel |
Output Signal
4 .. 20 mA |
Accuracy according to DIN 16086, terminal based
≤ ± 0.25 % FStyp. ≤ ± 0.5 % FS max. |
Accuracy(B.F.S.L.)
≤ ± 0.15 % FStyp. ≤ ± 0.25 % FS max. |
Zero/Range Temperature Drift
≤ ± 0.01 % FS / ° C typ. ≤ ± 0.01 % FS / ° C typ. |
Nonlinear according to DIN 16086, based on terminal
≤ ± 0.3 % FS max. |
Hysteresis
≤ ± 0.1 % FS max. |
Repeatability
≤ ± 0.1 % FS |
Rise Time
≤ 10 ms |
Long-term Stability
≤ ± 0.3 % FStyp. / year |
Compensation Temperature Range
-20 .. +85℃ |
Operating Temperature Range
-40 .. +100℃ /-25 .. +85℃ |
Storage Temperature Range
-40 .. +100℃ |
Fluid Temperature Range
-40 .. +125℃ /-25 .. +125℃ |
CE Certification
EN61000-6-1/2/3/4 |
Anti-vibration (DIN EN 60068-2-6 at 10 .. 2000 Hz)
≤ 20g |
Anti-impact (DIN EN 60068-2-27)
100 g / 6 ms / half-sine 500 g / 1 ms / half-sine |
Protection Level(DIN EN 60529)
IP67 |
Supply Voltage
9-36V |
Residual Ripple of Supply Voltage
≤ 5 % |
Current Consumption
≤ 25 mA |
Lifespan
> 10 million cycles , 0 .. 100 % FS |
Weight
~75g |
Measurement Range(bar)
250 |
Overload Pressure (bar)
500 |
Burst Pressure (bar)
1250 |
Mechanical Connection
G1/4 A |
Material of parts connected to the fluid
Stainless steel |
Output Signal
4 .. 20 mA |
Accuracy according to DIN 16086, terminal based
≤ ± 0.25 % FStyp. ≤ ± 0.5 % FS max. |
Accuracy(B.F.S.L.)
≤ ± 0.15 % FStyp. ≤ ± 0.25 % FS max. |
Zero/Range Temperature Drift
≤ ± 0.01 % FS / ° C typ. ≤ ± 0.01 % FS / ° C typ. |
Nonlinear according to DIN 16086, based on terminal
≤ ± 0.3 % FS max. |
Hysteresis
≤ ± 0.1 % FS max. |
Repeatability
≤ ± 0.1 % FS |
Rise Time
≤ 10 ms |
Long-term Stability
≤ ± 0.3 % FStyp. / year |
Compensation Temperature Range
-20 .. +85℃ |
Operating Temperature Range
-40 .. +100℃ /-25 .. +85℃ |
Storage Temperature Range
-40 .. +100℃ |
Fluid Temperature Range
-40 .. +125℃ /-25 .. +125℃ |
CE Certification
EN61000-6-1/2/3/4 |
Anti-vibration (DIN EN 60068-2-6 at 10 .. 2000 Hz)
≤ 20g |
Anti-impact (DIN EN 60068-2-27)
100 g / 6 ms / half-sine 500 g / 1 ms / half-sine |
Protection Level(DIN EN 60529)
IP67 |
Supply Voltage
9-36V |
Residual Ripple of Supply Voltage
≤ 5 % |
Current Consumption
≤ 25 mA |
Lifespan
> 10 million cycles , 0 .. 100 % FS |
Weight
~75g |
Measurement Range (bar)
400 |
Overload Pressure (bar)
800 |
Burst Pressure (bar)
2000 |
Mechanical Connection
G1/4 A |
Material of parts connected to the fluid
Stainless steel |
Output Signal
4 .. 20 mA |
Accuracy according to DIN 16086, terminal based
≤ ± 0.25 % FStyp. ≤ ± 0.5 % FS max. |
Accuracy(B.F.S.L.)
≤ ± 0.15 % FStyp. ≤ ± 0.25 % FS max. |
Zero/Range Temperature Drift
≤ ± 0.01 % FS / ° C typ. ≤ ± 0.01 % FS / ° C typ. |
Nonlinear according to DIN 16086, based on terminal
≤ ± 0.3 % FS max. |
Hysteresis
≤ ± 0.1 % FS max. |
Repeatability
≤ ± 0.1 % FS |
Rise Time
≤ 10 ms |
Long-term Stability
≤ ± 0.3 % FStyp. / year |
Compensation Temperature Range
-20 .. +85℃ |
Operating Temperature Range
-40 .. +100℃ /-25 .. +85℃ |
Storage Temperature Range
-40 .. +100℃ |
Fluid Temperature Range
-40 .. +125℃ /-25 .. +125℃ |
CE Certification
EN61000-6-1/2/3/4 |
Anti-vibration (DIN EN 60068-2-6 at 10 .. 2000 Hz)
≤ 20g |
Anti-impact (DIN EN 60068-2-27)
100 g / 6 ms / half-sine 500 g / 1 ms / half-sine |
Protection Level(DIN EN 60529)
IP67 |
Supply Voltage
9-36V |
Residual Ripple of Supply Voltage
≤ 5 % |
Current Consumption
≤ 25 mA |
Lifespan
> 10 million cycles , 0 .. 100 % FS |
Weight
~75g |
Measurement Range (bar)
600 |
Overload Pressure (bar)
10200 |
Burst Pressure (bar)
2000 |
Mechanical Connection
G1/4 A |
Material of parts connected to the fluid
Stainless steel |
Output Signal
4 .. 20 mA |
Accuracy according to DIN 16086, terminal based
≤ ± 0.25 % FStyp. ≤ ± 0.5 % FS max. |
Accuracy(B.F.S.L.)
≤ ± 0.15 % FStyp. ≤ ± 0.25 % FS max. |
Zero/Range Temperature Drift
≤ ± 0.01 % FS / ° C typ. ≤ ± 0.01 % FS / ° C typ. |
Nonlinear according to DIN 16086, based on terminal
≤ ± 0.3 % FS max. |
Hysteresis
≤ ± 0.1 % FS max. |
Repeatability
≤ ± 0.1 % FS |
Rise Time
≤ 10 ms |
Long-term Stability
≤ ± 0.3 % FStyp. / year |
Compensation Temperature Range
-20 .. +85℃ |
Operating Temperature Range
-40 .. +100℃ /-25 .. +85℃ |
Storage Temperature Range
-40 .. +100℃ |
Fluid Temperature Range
-40 .. +125℃ /-25 .. +125℃ |
CE Certification
EN61000-6-1/2/3/4 |
Anti-vibration (DIN EN 60068-2-6 at 10 .. 2000 Hz)
≤ 20g |
Anti-impact (DIN EN 60068-2-27)
100 g / 6 ms / half-sine 500 g / 1 ms / half-sine |
Protection Level(DIN EN 60529)
IP67 |
Supply Voltage
9-36V |
Residual Ripple of Supply Voltage
≤ 5 % |
Current Consumption
≤ 25 mA |
Lifespan
> 10 million cycles , 0 .. 100 % FS |
Weight
~75g |
Hotline:0086-021-37829910
Phone:+86 18916808200
Email:sales@smartsh.com
After submitting your information, our sales representative will contact you as soon as possible and send you the product documents.
Scan the QR code with WeChat and follow us to get in touch