Stock
001266
Global
Home Sensor Pressure ePST7000 Pressure Sensor
Consult
ePST7000 Pressure Sensor
The ePST7000 pressure sensor is a high performance product developed for safety circuits/safety functions. The shell is made of stainless steel material, with a compact overall volume, easy installation and high stability. It is an economical and cost-effective product widely used in construction machinery.
Phone:+86 18916808200
Product features
Strong and Durable

Excellent shock and vibration resistance, specially designed CDS system function, protection level up to IP69K, very suitable for the construction machinery industry in the harsh working environment.

High Security

Developed for safety circuits/safety functions with safety ratings up to SIL2 (IEC61508) or PLd (ISO13849) safety standard.

Technical Parameter
Model-0040Model-0060Model-0100Model-0160Model-0250Model-0400Model-0600
Basic parameters
Measurement Range (bar)

40

Overload Pressure (bar)

80

Burst Pressure (bar)

200

Mechanical Connection

G1/4 A

Material of parts connected to the fluid

Stainless steel

Output Data
Output Signal

4 .. 20 mA

Accuracy according to DIN 16086, terminal based

≤ ± 0.25 % FStyp.

≤ ± 0.5 % FS max.

Accuracy(B.F.S.L.)

≤ ± 0.15 % FStyp.

≤ ± 0.25 % FS max.

Zero/Range Temperature Drift

≤ ± 0.01 % FS / ° C typ.

≤ ± 0.01 % FS / ° C typ.

Nonlinear according to DIN 16086, based on terminal

≤ ± 0.3 % FS max.

Hysteresis

≤ ± 0.1 % FS max.

Repeatability

≤ ± 0.1 % FS

Rise Time

≤ 10 ms

Long-term Stability

≤ ± 0.3 % FStyp. / year

Environmental Conditions
Compensation Temperature Range

-20 .. +85℃

Operating Temperature Range

-40 .. +100℃ /-25 .. +85℃

Storage Temperature Range

-40 .. +100℃

Fluid Temperature Range

-40 .. +125℃ /-25 .. +125℃

CE Certification

EN61000-6-1/2/3/4

Anti-vibration (DIN EN 60068-2-6 at 10 .. 2000 Hz)

≤ 20g

Anti-impact (DIN EN 60068-2-27)

100 g / 6 ms / half-sine

500 g / 1 ms / half-sine

Protection Level(DIN EN 60529)

IP67

Other Parameters
Supply Voltage

9-36V

Residual Ripple of Supply Voltage

≤ 5 %

Current Consumption

≤ 25 mA

Lifespan

> 10 million cycles , 0 .. 100 % FS

Weight

~75g

Basic parameters
Measurement Rang (bar)

60

Overload Pressure (bar)

120

Burst Pressure (bar)

300

Mechanical Connection

G1/4 A

Material of parts connected to the fluid

Stainless steel

Output Data
Output Signal

4 .. 20 mA

Accuracy according to DIN 16086, terminal based

≤ ± 0.25 % FStyp.

≤ ± 0.5 % FS max.

Accuracy(B.F.S.L.)

≤ ± 0.15 % FStyp.

≤ ± 0.25 % FS max.

Zero/Range Temperature Drift

≤ ± 0.01 % FS / ° C typ.

≤ ± 0.01 % FS / ° C typ.

Nonlinear according to DIN 16086, based on terminal

≤ ± 0.3 % FS max.

Hysteresis

≤ ± 0.1 % FS max.

Repeatability

≤ ± 0.1 % FS

Rise Time

≤ 10 ms

Long-term Stability

≤ ± 0.3 % FStyp. / year

Environmental Conditions
Compensation Temperature Range

-20 .. +85℃

Operating Temperature Range

-40 .. +100℃ /-25 .. +85℃

Storage Temperature Range

-40 .. +100℃

Fluid Temperature Range

-40 .. +125℃ /-25 .. +125℃

CE Certification

EN61000-6-1/2/3/4

Anti-vibration (DIN EN 60068-2-6 at 10 .. 2000 Hz)

≤ 20g

Anti-impact (DIN EN 60068-2-27)

100 g / 6 ms / half-sine

500 g / 1 ms / half-sine

Protection Level(DIN EN 60529)

IP67

Other Parameters
Supply Voltage

9-36V

Residual Ripple of Supply Voltage

≤ 5 %

Current Consumption

≤ 25 mA

Lifespan

> 10 million cycles , 0 .. 100 % FS

Weight

~75g

Basic parameters
Measurement Range (bar)

100

Overload Pressure (bar)

200

Burst Pressure (bar)

500

Mechanical Connection

G1/4 A

Material of parts connected to the fluid

Stainless steel

Output Data
Output Signal

4 .. 20 mA

Accuracy according to DIN 16086, terminal based

≤ ± 0.25 % FStyp.

≤ ± 0.5 % FS max.

Accuracy(B.F.S.L.)

≤ ± 0.15 % FStyp.

≤ ± 0.25 % FS max.

Zero/Range Temperature Drift

≤ ± 0.01 % FS / ° C typ.

≤ ± 0.01 % FS / ° C typ.

Nonlinear according to DIN 16086, based on terminal

≤ ± 0.3 % FS max.

Hysteresis

≤ ± 0.1 % FS max.

Repeatability

≤ ± 0.1 % FS

Rise Time

≤ 10 ms

Long-term Stability

≤ ± 0.3 % FStyp. / year

Environmental Conditions
Compensation Temperature Range

-20 .. +85℃

Operating Temperature Range

-40 .. +100℃ /-25 .. +85℃

Storage Temperature Range

-40 .. +100℃

Fluid Temperature Range

-40 .. +125℃ /-25 .. +125℃

CE Certification

EN61000-6-1/2/3/4

Anti-vibration (DIN EN 60068-2-6 at 10 .. 2000 Hz)

≤ 20g

Anti-impact (DIN EN 60068-2-27)

100 g / 6 ms / half-sine

500 g / 1 ms / half-sine

Protection Level(DIN EN 60529)

IP67

Other Parameters
Supply Voltage

9-36V

Residual Ripple of Supply Voltage

≤ 5 %

Current Consumption

≤ 25 mA

Lifespan

> 10 million cycles , 0 .. 100 % FS

Weight

~75g

Basic parameters
Measurement Range(bar)

160

Overload Pressure (bar)

320

Burst Pressure (bar)

800

Mechanical Connection

G1/4 A

Material of parts connected to the fluid

Stainless steel

Output Data
Output Signal

4 .. 20 mA

Accuracy according to DIN 16086, terminal based

≤ ± 0.25 % FStyp.

≤ ± 0.5 % FS max.

Accuracy(B.F.S.L.)

≤ ± 0.15 % FStyp.

≤ ± 0.25 % FS max.

Zero/Range Temperature Drift

≤ ± 0.01 % FS / ° C typ.

≤ ± 0.01 % FS / ° C typ.

Nonlinear according to DIN 16086, based on terminal

≤ ± 0.3 % FS max.

Hysteresis

≤ ± 0.1 % FS max.

Repeatability

≤ ± 0.1 % FS

Rise Time

≤ 10 ms

Long-term Stability

≤ ± 0.3 % FStyp. / year

Environmental Conditions
Compensation Temperature Range

-20 .. +85℃

Operating Temperature Range

-40 .. +100℃ /-25 .. +85℃

Storage Temperature Range

-40 .. +100℃

Fluid Temperature Range

-40 .. +125℃ /-25 .. +125℃

CE Certification

EN61000-6-1/2/3/4

Anti-vibration (DIN EN 60068-2-6 at 10 .. 2000 Hz)

≤ 20g

Anti-impact (DIN EN 60068-2-27)

100 g / 6 ms / half-sine

500 g / 1 ms / half-sine

Protection Level(DIN EN 60529)

IP67

Other Parameters
Supply Voltage

9-36V

Residual Ripple of Supply Voltage

≤ 5 %

Current Consumption

≤ 25 mA

Lifespan

> 10 million cycles , 0 .. 100 % FS

Weight

~75g

Basic parameters
Measurement Range(bar)

250

Overload Pressure (bar)

500

Burst Pressure (bar)

1250

Mechanical Connection

G1/4 A

Material of parts connected to the fluid

Stainless steel

Output Data
Output Signal

4 .. 20 mA

Accuracy according to DIN 16086, terminal based

≤ ± 0.25 % FStyp.

≤ ± 0.5 % FS max.

Accuracy(B.F.S.L.)

≤ ± 0.15 % FStyp.

≤ ± 0.25 % FS max.

Zero/Range Temperature Drift

≤ ± 0.01 % FS / ° C typ.

≤ ± 0.01 % FS / ° C typ.

Nonlinear according to DIN 16086, based on terminal

≤ ± 0.3 % FS max.

Hysteresis

≤ ± 0.1 % FS max.

Repeatability

≤ ± 0.1 % FS

Rise Time

≤ 10 ms

Long-term Stability

≤ ± 0.3 % FStyp. / year

Environmental Conditions
Compensation Temperature Range

-20 .. +85℃

Operating Temperature Range

-40 .. +100℃ /-25 .. +85℃

Storage Temperature Range

-40 .. +100℃

Fluid Temperature Range

-40 .. +125℃ /-25 .. +125℃

CE Certification

EN61000-6-1/2/3/4

Anti-vibration (DIN EN 60068-2-6 at 10 .. 2000 Hz)

≤ 20g

Anti-impact (DIN EN 60068-2-27)

100 g / 6 ms / half-sine

500 g / 1 ms / half-sine

Protection Level(DIN EN 60529)

IP67

Other Parameters
Supply Voltage

9-36V

Residual Ripple of Supply Voltage

≤ 5 %

Current Consumption

≤ 25 mA

Lifespan

> 10 million cycles , 0 .. 100 % FS

Weight

~75g

Basic parameters
Measurement Range (bar)

400

Overload Pressure (bar)

800

Burst Pressure (bar)

2000

Mechanical Connection

G1/4 A

Material of parts connected to the fluid

Stainless steel

Output Data
Output Signal

4 .. 20 mA

Accuracy according to DIN 16086, terminal based

≤ ± 0.25 % FStyp.

≤ ± 0.5 % FS max.

Accuracy(B.F.S.L.)

≤ ± 0.15 % FStyp.

≤ ± 0.25 % FS max.

Zero/Range Temperature Drift

≤ ± 0.01 % FS / ° C typ.

≤ ± 0.01 % FS / ° C typ.

Nonlinear according to DIN 16086, based on terminal

≤ ± 0.3 % FS max.

Hysteresis

≤ ± 0.1 % FS max.

Repeatability

≤ ± 0.1 % FS

Rise Time

≤ 10 ms

Long-term Stability

≤ ± 0.3 % FStyp. / year

Environmental Conditions
Compensation Temperature Range

-20 .. +85℃

Operating Temperature Range

-40 .. +100℃ /-25 .. +85℃

Storage Temperature Range

-40 .. +100℃

Fluid Temperature Range

-40 .. +125℃ /-25 .. +125℃

CE Certification

EN61000-6-1/2/3/4

Anti-vibration (DIN EN 60068-2-6 at 10 .. 2000 Hz)

≤ 20g

Anti-impact (DIN EN 60068-2-27)

100 g / 6 ms / half-sine

500 g / 1 ms / half-sine

Protection Level(DIN EN 60529)

IP67

Other Parameters
Supply Voltage

9-36V

Residual Ripple of Supply Voltage

≤ 5 %

Current Consumption

≤ 25 mA

Lifespan

> 10 million cycles , 0 .. 100 % FS

Weight

~75g

Basic parameters
Measurement Range (bar)

600

Overload Pressure (bar)

10200

Burst Pressure (bar)

2000

Mechanical Connection

G1/4 A

Material of parts connected to the fluid

Stainless steel

Output Data
Output Signal

4 .. 20 mA

Accuracy according to DIN 16086, terminal based

≤ ± 0.25 % FStyp.

≤ ± 0.5 % FS max.

Accuracy(B.F.S.L.)

≤ ± 0.15 % FStyp.

≤ ± 0.25 % FS max.

Zero/Range Temperature Drift

≤ ± 0.01 % FS / ° C typ.

≤ ± 0.01 % FS / ° C typ.

Nonlinear according to DIN 16086, based on terminal

≤ ± 0.3 % FS max.

Hysteresis

≤ ± 0.1 % FS max.

Repeatability

≤ ± 0.1 % FS

Rise Time

≤ 10 ms

Long-term Stability

≤ ± 0.3 % FStyp. / year

Environmental Conditions
Compensation Temperature Range

-20 .. +85℃

Operating Temperature Range

-40 .. +100℃ /-25 .. +85℃

Storage Temperature Range

-40 .. +100℃

Fluid Temperature Range

-40 .. +125℃ /-25 .. +125℃

CE Certification

EN61000-6-1/2/3/4

Anti-vibration (DIN EN 60068-2-6 at 10 .. 2000 Hz)

≤ 20g

Anti-impact (DIN EN 60068-2-27)

100 g / 6 ms / half-sine

500 g / 1 ms / half-sine

Protection Level(DIN EN 60529)

IP67

Other Parameters
Supply Voltage

9-36V

Residual Ripple of Supply Voltage

≤ 5 %

Current Consumption

≤ 25 mA

Lifespan

> 10 million cycles , 0 .. 100 % FS

Weight

~75g

Get the product that suits you now
Embark on a brand new digital upgrade
Product
Consultation

Hotline:0086-021-37829910

Phone:+86 18916808200

Email:sales@smartsh.com

Retrieve Document

After submitting your information, our sales representative will contact you as soon as possible and send you the product documents.

* Please Select After-Sales Type
Online
Consultation
Contact US

Scan the QR code with WeChat and follow us to get in touch

+86 18916808200 Telephone
sales@smartsh.com Sales email
tech@smartsh.com Technical support
hr@smartsh.com Resume submission
Working hours are from 9am to 6pm Monday to Friday.